{"id":21,"date":"2017-06-23T10:26:15","date_gmt":"2017-06-23T10:26:15","guid":{"rendered":"http:\/\/peoplespower.com.np\/?page_id=21"},"modified":"2018-01-26T09:49:45","modified_gmt":"2018-01-26T09:49:45","slug":"project","status":"publish","type":"page","link":"https:\/\/peoplespower.com.np\/index.php\/project\/","title":{"rendered":"Projects"},"content":{"rendered":"<p>[vc_row][vc_column][vc_empty_space][vc_column_text]<span style=\"font-weight: 400;\">We are dedicated promoting different hydro and energy projects in Nepal. We carry out several researches, technical and economic feasibility studies, <\/span><span style=\"font-weight: 400;\">environmental and social assessments. Considering the finding of researches and studies we engage to promote different hydro projects.<\/span><\/p>\n<p><strong>People&#8217;s Power Limited is implementing the following projects :<\/strong>[\/vc_column_text][vc_empty_space][\/vc_column][\/vc_row][vc_row][vc_column][vc_tta_accordion][vc_tta_section title=&#8221;Puwa II&#8221; tab_id=&#8221;1514999552917-8cced8cf-b6ea&#8221;][vc_column_text]<b>Introduction:<\/b><\/p>\n<p><span style=\"font-weight: 400;\">Puwa II is the first project being developed by People&#8217;s Power Limited in Puwa Khola in Ilam district. The capacity of the project is 4.96 megawatt\u00a0(MW).<\/span> <span style=\"font-weight: 400;\">The Puwa II hydroelectric project is located in Ilam Municipality ward no 1, Sakhejung and ward no 4 Maipokhari. <\/span><\/p>\n<p><span style=\"font-weight: 400;\">This project has a very easy road access. \u00a0It is 680 KM to reach Ilam Bazar from Kathmandu via road transportation. Similarly, Ilam can be reached; Kathmandu to Bhadrapur via airplane and Bhadrapur to Ilam via 100 KM road transportation. It is 14 KM to get project&#8217;s water intake location which is in the Mechi highway. It is 8 KM road transportation to get headworks and Power house from water intake. Having easy road access to powerhouse and water intake is an added value for this project.<\/span><\/p>\n<p><b>Financial Aspect:<\/b><\/p>\n<p><span style=\"font-weight: 400;\">Total investment of this project is 90 Crore where 60 Crore will be generated by Bank Loan and 30 Crore will be collected by promoter&#8217;s investment. It is projected to produce 2,79,76,623 units electricity in every year where 1,95,71,299 units will be produced in wet season in 6 months and 84,05,324 units in the dry season in 6 months. Selling price will be 4.8\/unit in wet season and 8.4\/unit in dry season.<\/span><\/p>\n<p><b>Silent Features:<\/b><\/p>\n<table>\n<tbody>\n<tr>\n<td><b>River<\/b><\/td>\n<td>Puwa Khola<\/td>\n<\/tr>\n<tr>\n<td><b>Municipality<\/b><\/td>\n<td><b>Ilam (Sakhejung &amp; Mai Pokhari)<\/b><\/td>\n<\/tr>\n<tr>\n<td><b>District<\/b><\/td>\n<td>Ilam<\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">Zone<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Mechi<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">Catchment Area<\/span><\/td>\n<td><span style=\"font-weight: 400;\">63.9 Sq Km<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">Design Discharge<\/span><\/td>\n<td><span style=\"font-weight: 400;\">2.72 Cum\/Sec.<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">Marketable Annual Energy<\/span><\/td>\n<td><span style=\"font-weight: 400;\">27.98 GWh<\/span><\/td>\n<\/tr>\n<tr>\n<td><b>Weir<\/b><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">Type of Weir<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Ogee type<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">Size of Weir<\/span><span style=\"font-weight: 400;\"> \u00a0<\/span><\/td>\n<td><span style=\"font-weight: 400;\">2.3 m length x 1.7 m width<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">Weir Crest <\/span><b>Level<\/b><\/td>\n<td><span style=\"font-weight: 400;\">El. 1195 m<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">Flood Discharge(1:100 yrs)<\/span><\/td>\n<td><span style=\"font-weight: 400;\">348 cum\/sec<\/span><\/td>\n<\/tr>\n<tr>\n<td><b>Headworks<\/b><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">Type of intake<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Side intake<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">Size of intake<\/span><\/td>\n<td><span style=\"font-weight: 400;\">2.0mx0.8m<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">Orifice Top level<\/span><\/td>\n<td><span style=\"font-weight: 400;\">El. 1195m<\/span><\/td>\n<\/tr>\n<tr>\n<td><b>Gravel Trap<\/b><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">Section<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Rectangular<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">Size(WxH)<\/span><\/td>\n<td><span style=\"font-weight: 400;\">5m x 3.5 m<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">Length<\/span><\/td>\n<td><span style=\"font-weight: 400;\">8.00 m<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">U\/S Transition Length<\/span><\/td>\n<td><span style=\"font-weight: 400;\">3.0 m<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">Spillway Type<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Overflow side spillway<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">Spillway Length<\/span><\/td>\n<td><span style=\"font-weight: 400;\">10.00 m<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">Gravel Flushing Gate Size<\/span><\/td>\n<td><span style=\"font-weight: 400;\">0.7 m x 0.7 m (1 number)<\/span><\/td>\n<\/tr>\n<tr>\n<td><b>Headrace \u00a0Canal<\/b><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">Section<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Rectangular covered concrete canal<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">Size(WxH)<\/span><\/td>\n<td><span style=\"font-weight: 400;\">1.7 m x 1.2 m<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">Length<\/span><\/td>\n<td><span style=\"font-weight: 400;\">270 m<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">Hydraulic Slope<\/span><\/td>\n<td><span style=\"font-weight: 400;\">1:500<\/span><\/td>\n<\/tr>\n<tr>\n<td><b>Desanding Basin<\/b><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">Type \u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0<\/span><\/td>\n<td><span style=\"font-weight: 400;\"> \u00a0Dufour, Continuous\/Intermittent \u00a0\u00a0\u00a0\u00a0\u00a0flushing \u00a0<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">Size(L<\/span><span style=\"font-weight: 400;\">ef<\/span><span style=\"font-weight: 400;\">xBxH)<\/span><\/td>\n<td><span style=\"font-weight: 400;\">51.0 m x 8.0 m x 6.00 m<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">Transition Length<\/span><\/td>\n<td><span style=\"font-weight: 400;\">13.0 m<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">Desanding Chambers<\/span><\/td>\n<td><span style=\"font-weight: 400;\">2 no.<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">Particle Size to be settled<\/span><\/td>\n<td><span style=\"font-weight: 400;\">0.20 mm<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">Flushing Gate Size<\/span><\/td>\n<td><span style=\"font-weight: 400;\">1.0 m x 1.0 m (1 number)<\/span><\/td>\n<\/tr>\n<tr>\n<td><b>Back Transition<\/b><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">Type <\/span><\/td>\n<td><span style=\"font-weight: 400;\"> \u00a0\u00a0\u00a0\u00a0\u00a0Rectangular \u00a0<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">Size(L<\/span><span style=\"font-weight: 400;\">ef<\/span><span style=\"font-weight: 400;\">xBxH)<\/span><\/td>\n<td><span style=\"font-weight: 400;\">15.00 m x 8.00 m x 6.0 m<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">Particle Size to be settled<\/span><\/td>\n<td><span style=\"font-weight: 400;\">less than 0.20 mm<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">Flushing Gate Size<\/span><\/td>\n<td><span style=\"font-weight: 400;\">0.7 m x 0.7 m (1 number)<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">Capacity<\/span><\/td>\n<td><span style=\"font-weight: 400;\">684.00 m<\/span><span style=\"font-weight: 400;\">3<\/span><span style=\"font-weight: 400;\"> (Volume for 3 minutes Generation)<\/span><\/td>\n<\/tr>\n<tr>\n<td><b>Penstock<\/b><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">Type<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Exposed<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">Material<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Steel<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">Length<\/span><\/td>\n<td><span style=\"font-weight: 400;\">3800.00 m (uniform diameter)<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">Diameter<\/span><\/td>\n<td><span style=\"font-weight: 400;\">1.10 m<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">Thickness<\/span><\/td>\n<td><span style=\"font-weight: 400;\">8 mm to 22 mm<\/span><\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td><b>Powerhouse<\/b><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">Type of Powerhouse<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Surface<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">Size (LxBxH)<\/span><\/td>\n<td><span style=\"font-weight: 400;\">30.00 m x 15.00 m x 15.00 m (Roof ridge)<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">Floor level<\/span><\/td>\n<td><span style=\"font-weight: 400;\">947.40 m<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">Minimum Tail water level<\/span><\/td>\n<td><span style=\"font-weight: 400;\">949.5 m<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">Turbine axis<\/span><\/td>\n<td><span style=\"font-weight: 400;\">953.0 m<\/span><\/td>\n<\/tr>\n<tr>\n<td><b>Turbine<\/b><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">Type of Turbine<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Pelton, Horizontal<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">No. of Units<\/span><\/td>\n<td><span style=\"font-weight: 400;\">2<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">Rated Net Head<\/span><\/td>\n<td><span style=\"font-weight: 400;\">217-239m<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">Unit Discharge<\/span><\/td>\n<td><span style=\"font-weight: 400;\">1.36 cum\/sec<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">Axis<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Horizontal<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">Rated Speed<\/span><\/td>\n<td><span style=\"font-weight: 400;\">600 rpm.<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">Runaway Speed<\/span><\/td>\n<td><span style=\"font-weight: 400;\">900 rpm.<\/span><\/td>\n<\/tr>\n<tr>\n<td><b>Generator<\/b><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">Type of Generator <\/span><\/td>\n<td><span style=\"font-weight: 400;\">Synchronous AC 3 phase<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">Max Rated Capacity<\/span><\/td>\n<td><span style=\"font-weight: 400;\">3000 KVA<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">Rated Voltage<\/span><\/td>\n<td><span style=\"font-weight: 400;\">6.6 KV<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">Power Factor<\/span><\/td>\n<td><span style=\"font-weight: 400;\">0.85<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">No of pole<\/span><\/td>\n<td><span style=\"font-weight: 400;\">10<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">No of unit<\/span><\/td>\n<td><span style=\"font-weight: 400;\">2<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">Frequency<\/span><\/td>\n<td><span style=\"font-weight: 400;\">50Hz<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">Excitation System<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Brushless<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">Efficiency<\/span><\/td>\n<td><span style=\"font-weight: 400;\">96%<\/span><\/td>\n<\/tr>\n<tr>\n<td><b>Sub-station<\/b><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">Type<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Outdoor<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">Power Transformers<\/span><\/td>\n<td><span style=\"font-weight: 400;\">6.6\/33 kV, 3 phase<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">Type<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Oil immersed self-cooled outdoor type (ONAN)<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">Rated Capacity<\/span><\/td>\n<td><span style=\"font-weight: 400;\">3700 kVA<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">Number of Units<\/span><\/td>\n<td><span style=\"font-weight: 400;\">2<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">Frequency<\/span><\/td>\n<td><span style=\"font-weight: 400;\">50 Hz<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">Number of Phase<\/span><\/td>\n<td><span style=\"font-weight: 400;\">3 phase<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">Voltage Ratio<\/span><\/td>\n<td><span style=\"font-weight: 400;\">6.6\/33kvs<\/span><\/td>\n<\/tr>\n<tr>\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td><b>Transmission Line<\/b><\/td>\n<td><span style=\"font-weight: 400;\">About 5 km long 33 kV single circuit ACSR Dog Conductor, connected to Upper Puwa I Sub Station<\/span> <span style=\"font-weight: 400;\">ACSR Dog Conductor, connected to Upper Puwa I Substation<\/span><\/td>\n<\/tr>\n<tr>\n<td><b>Energy<\/b><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">Installed Capacity<\/span><\/td>\n<td>4,960 KW<\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">Annual Wet Energy<\/span><\/td>\n<td>19.57 GWh<\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">Annual Dry Energy<\/span><\/td>\n<td><span style=\"font-weight: 400;\">\u00a08.41 GWh<\/span><\/td>\n<\/tr>\n<tr>\n<td>Total Annual Energy<\/td>\n<td>27.98 GWh<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><b>Financial Indicators:<\/b><\/p>\n<table>\n<tbody>\n<tr>\n<td><span style=\"font-weight: 400;\">Total Project Cost (Including IDC)<\/span><\/td>\n<td><span style=\"font-weight: 400;\">90 Crore<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">Project Financing (Debt\/Equity Ratio)<\/span><\/td>\n<td>2:1<\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">Debt Interest Rate<\/span><\/td>\n<td><span style=\"font-weight: 400;\">10%<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">Internal Rate of Return (IRR)<\/span><\/td>\n<td>14.07%<\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">Benefit\/Cost Ratio (B\/C Ratio)<\/span><\/td>\n<td><span style=\"font-weight: 400;\">1.16<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">Project Payback Period<\/span><\/td>\n<td><span style=\"font-weight: 400;\">12 years<\/span><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>[\/vc_column_text][\/vc_tta_section][vc_tta_section title=&#8221;Other Project&#8221; tab_id=&#8221;1514999552965-12546b0b-c192&#8243;][vc_column_text]<span style=\"font-weight: 400;\">Once the construction of Puwa II started, we are intensively engaged on research, assessment and study of viable projects. We are having meetings with different agencies potentially engaged on hydro project development aiming to have partnership to develop different hydro and energy projects in Nepal.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">We will update about our upcoming projects once some concrete progress achieved. <\/span>[\/vc_column_text][\/vc_tta_section][\/vc_tta_accordion][\/vc_column][\/vc_row]<\/p>\n","protected":false},"excerpt":{"rendered":"<p>[vc_row][vc_column][vc_empty_space][vc_column_text]We are dedicated promoting different hydro and energy projects in Nepal. We carry out several researches, technical and economic feasibility studies, environmental and social assessments. Considering the finding of researches and studies we engage to promote different hydro projects. People&#8217;s Power Limited is implementing the following projects :[\/vc_column_text][vc_empty_space][\/vc_column][\/vc_row][vc_row][vc_column][vc_tta_accordion][vc_tta_section title=&#8221;Puwa II&#8221; tab_id=&#8221;1514999552917-8cced8cf-b6ea&#8221;][vc_column_text]Introduction: Puwa II is the<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-21","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/peoplespower.com.np\/index.php\/wp-json\/wp\/v2\/pages\/21","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/peoplespower.com.np\/index.php\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/peoplespower.com.np\/index.php\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/peoplespower.com.np\/index.php\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/peoplespower.com.np\/index.php\/wp-json\/wp\/v2\/comments?post=21"}],"version-history":[{"count":12,"href":"https:\/\/peoplespower.com.np\/index.php\/wp-json\/wp\/v2\/pages\/21\/revisions"}],"predecessor-version":[{"id":1445,"href":"https:\/\/peoplespower.com.np\/index.php\/wp-json\/wp\/v2\/pages\/21\/revisions\/1445"}],"wp:attachment":[{"href":"https:\/\/peoplespower.com.np\/index.php\/wp-json\/wp\/v2\/media?parent=21"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}